Skip to main content

Advanced Diaphragm Position Control - API674 & API675 Pumps

 

Our Technology Advantages - Creating Real Value for Our Customers

 

Advanced Diaphragm Position Control (ADPC) - API674 Pumps

 
 

Protecting the Diaphragm from Closed Suction Line & Suction Line Vacuum Conditions

 

In normal operation the Hydra-Cell® diaphragms operate in hydraulic balance. If there is a restriction in the suction line of the pump the Advanced Diaphragm Position Control (ADPC) comes into play and protects the diaphragm from damage; obviously the discharge flow rate is effected.

If an operator runs the Hydra-Cell® pump by accident with a closed suction line isolation valve, the diaphragms are not damaged.

If there is a vacuum condition on the suction of a running pump the ADPC keeps the diaphragm safe from rupture.

Wanner first introduced this patented technology in 2003 and still continues to improve the designs and patents to improve the performance, security and peace of mind for our customers.

 

 Watch the Hydra-Cell® Q155 restricted inlet demonstration video

 
 
 
 

Self-Priming and Dry Suction Lift

 

The Hydra-Cell® pump can run dry indefinitely, this combined with the pump's ability to pull approximately an 80% vacuum gives the pump the ability to dry lift and self prime.

 

Wide Range of Suction Pressures

 

The standard Hydra-Cell® pump can operate from negative 0.5 barg to plus 34 barg, giving flexibility for many different applications and simplifying system design. For higher suction pressures please consult Wanner International.